Raman spectroscopy - advanced optical analysis technology
Boost plant safety, ensure product quality, and optimize operations. Raman spectroscopy measures the composition and molecular structure of your samples from lab-to-process in real time.
785 nm
Body: 316L stainless steel
Window: optical-grade materials
ATEX, CSA, IECEx, UKCA, JPEx
For solids and semi-solids analysis, the Raman Rxn-20 probe reigns supreme. Its state-of-the-art, stainless-steel probe design produces representative, focus-free, quantitative Raman measurements. The Rxn-20 probe illuminates a large surface area and eliminates the need to align the probe for surface roughness. It provides heterogenous solids sampling via volumetric analysis, which is highly useful for measuring tablets, capsules, food solids, and polymer beads.
Chemicals: final product quality, blend impurities, crystallinity, raw materials
Polymers: extruded pellet quality, crystallinity, density, raw materials
Pharmaceutical: crystallinity, polymorphism, granulation, blend uniformity, content uniformity, coating, tableting
Food & Beverage: quality of dairy solids, meat and fish composition
Non-contact measurement of heterogeneous solids for better representation
Improved process control and efficiency through faster measurements
Non-destructive measurements from a distance
Reproducible sampling
Sampling flexibility with a variety of focus-free and immersion Rxn-20 accessory optics
No need to align probe for surface roughness
Surface and deep layer (volumetric) analysis
High-end products
Technical excellence
Simplicity
Standard products
Technical excellence
Simplicity
Specialized products
Technical excellence
Simplicity
Variable
| FLEX selections | Technical excellence | Simplicity |
|---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Informationen zu Inbetriebnahme, Bedienung und Wartung
der Raman Rxn‑20-Sonde
|
Language: |
German |
|
Version: |
07/10/2024 |
|
File size: |
1.7 MB |
|
File name: |
BA02167CDE_0222.pdf |
Hazardous area certifications and installation instructions
for the Raman Rxn-20 probe
| EN | |||
|
21/06/2024
|
|
|
|
|
08/08/2023
|
|
|
|
Language: |
English |
|
Version: |
21/06/2024 |
|
File size: |
893.6 KB |
|
File name: |
XA02747CEN_0424.pdf |
A list of published technical articles related to Biopharma 4.0
topics with recommendations from Life Science industry experts
at Endress+Hauser.
|
Language: |
English |
|
Version: |
26/06/2025 |
|
File size: |
363.4 KB |
|
File name: |
PU01611CEN_0125.pdf |
Ein Leitfaden zu unseren Anwendungshinweisen zur
Raman-Spektroskopie für die Life-Science-Industrie
(Raman Rxn2-Analysator, Raman Rxn4-Analysator,
Rxn-10-Sonde, Rxn-20-Sonde, Rxn-45-Sonde,
Rxn-46-Sonde und Zubehör für Sondenoptiken
(blO-Optic, Raman- Single Use-Optiksystem
/ SUB, Immersionsoptik, berührungslose Optik)
|
Language: |
German |
|
Version: |
24/09/2025 |
|
File size: |
1.4 MB |
|
File name: |
PU01447CDE_0222_Raman-Anwendungsleitfaden_LSI_web.pdf |
A guide to our Raman spectroscopy application notes for the
Life Science industry (featuring the Raman Rxn2 analyzer,
Raman Rxn4 analyzer, Rxn-10 probe, Rxn-20 probe, Rxn-45 probe,
Rxn-46 probe, and probe accessory optics (bIO-Optic, Raman single
use optic system / SUB, immersion optic, non-contact optic).
|
Language: |
English |
|
Version: |
19/04/2022 |
|
File size: |
1.1 MB |
|
File name: |
PU01447CEN_0222.pdf |
A list of definitions and sources for frequently used terms and
abbreviations in the biopharmaceutical industry related to
Biopharma 4.0.
|
Language: |
English |
|
Version: |
17/06/2025 |
|
File size: |
445 KB |
|
File name: |
PU01610CEN_0125.pdf |
ライフサイエンス産業向けラマン分光法アプリケーションノート(
ラマンRxn2アナライザー、ラマンRxn4アナライザー、Rxn-10プロー
ブ、Rxn-20プローブ、Rxn-45プローブ、Rxn-46プローブ、プローブ
オプティックアクセサリ(bIOオプティック、シングルユース向け
ラマンオプティックシステム/SUB、浸漬オプティック、非接触オプ
ティック)。
|
Language: |
Japanese |
|
Version: |
02/08/2024 |
|
File size: |
1.4 MB |
|
File name: |
PU01447CJA_0222_Raman_App_Guide_for_LifeScience.pdf |
本ガイドでは、食品・飲料業界におけるラマン分光法のアプリケー
ションノートについてご紹介しています。Raman Rxn2アナライザ、
Raman Rxn4アナライザ、Rxn-10プローブ、Rxn-20プローブ、Rxn-45
プローブ、ならびに浸漬式オプティックおよび非接触式オプティッ
クを用いた研究事例を取り上げています。
|
Language: |
Japanese |
|
Version: |
30/10/2025 |
|
File size: |
1.4 MB |
|
File name: |
CP01489CJA_0122_Raman Use in Food and Beverage.pdf |
A guide to Raman spectroscopy application notes for the
food & beverage industry (featuring studies using the
Raman Rxn2 analyzer, Raman Rxn4 analyzer, Rxn-10 probe,
Rxn-20 probe, Rxn-45 probe, and the immersion optic
and non-contact optic).
|
Language: |
English |
|
Version: |
17/02/2022 |
|
File size: |
859 KB |
|
File name: |
CP01489CEN_0122.pdf |
プロセスラインにおける信頼性の高い組成測定
|
Language: |
Japanese |
|
Version: |
01/03/2023 |
|
File size: |
16.4 MB |
|
File name: |
IN01223CJA_0121.pdf |