Deltatop DP73B

Product picture of: Deltatop DP73B

This product is no longer available.

Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.

Features and specifications

Back

Details

  • Measuring principle

    Differential pressure

  • Product headline

    Calculated volume or mass flow measurement. dp primary element (Pitot).

    NAFTA-version. Averaging pitot tube with 1-3/8" bullet profile.

  • Sensor features

    Insertion system.

    Pipe size DN300...4800 ; 12...192".

    Retractable version available.

    Compact or remote design.

    Deltabar S/M differential pressure transmitter.

  • Nominal diameter range

    12" ... 192"

  • Max. measurement error

    typically 1% of calculated volume or mass.

    Uncertainty of primary element excluding uncertainty of density or compensation.

  • Measuring range

    2'500 ... 2'000'000 m3/h

    1'500 ... 1'200'000 ACFM

  • Max. process pressure

    Cl.150 ... 2500

  • Medium temperature range

    Compact version:

    -200°C ... 200°C

    -328°F ... 392°F



    Remote version:

    -200°C ... 1000°C

    -328°F ... 1832°F

  • Degree of protection

    Transmitter (Deltabar):

    IP67

    NEMA6P

  • Display/Operation

    Transmitter (Deltabar):

    4-line display

    3 push buttons

    Quick setup

    HistoROM

  • Outputs

    Transmitter (Deltabar):

    4 ... 20 mA

  • Digital communication

    Transmitter (Deltabar):

    HART

    PROFIBUS PA

    FOUNDATION Fieldbus

  • Hazardous area approvals

    Transmitter (Deltabar):

    ATEX

    FM

    CSA

    IEC

    TIIS

    NEPSI

  • Measuring principle

    Differential pressure

  • Product headline

    Calculated volume or mass flow measurement. dp primary element (Pitot).

    NAFTA-version. Averaging pitot tube with 1-3/8" bullet profile.

  • Sensor features

    Insertion system.

    Pipe size DN300...4800 ; 12...192".

    Retractable version available.

    Compact or remote design.

    Deltabar S/M differential pressure transmitter.

  • Nominal diameter range

    12" ... 192"

  • Max. measurement error

    typically 1% of calculated volume or mass.

  • Measuring range

    100 ... 70'000m3/h
    400 ... 310'000 USGPM

  • Max. process pressure

    Cl.150 ... 2500

  • Medium temperature range

    Compact version:

    -200°C ... 200°C

    -328°F ... 392°F



    Remote version:

    -200°C ... 1000°C

    -328°F ... 1832°F

  • Degree of protection

    Transmitter (Deltabar):

    IP67

    NEMA6P

  • Display/Operation

    Transmitter (Deltabar):

    4-line display

    3 push buttons

    Quick setup

    HistoROM

  • Outputs

    Transmitter (Deltabar):

    4 ... 20 mA

  • Digital communication

    Transmitter (Deltabar):

    HART

    PROFIBUS PA

    FOUNDATION Fieldbus

  • Hazardous area approvals

    Transmitter (Deltabar):

    ATEX

    FM

    CSA

    IEC

    TIIS

    NEPSI

  • Measuring principle

    Differential pressure

  • Product headline

    Calculated volume or mass flow measurement. dp primary element (Pitot).

    NAFTA-version. Averaging pitot tube with 1-3/8" bullet profile.

  • Sensor features

    Insertion system.

    Pipe size DN300...4800 ; 12...192".

    Retractable version available.

    Compact or remote design.

    Deltabar S/M differential pressure transmitter.

  • Nominal diameter range

    12" ... 192"

  • Max. measurement error

    typically 1% of calculated volume or mass.

    Uncertainty of primary element excluding uncertainty of density or compensation.

  • Measuring range

    2'500 ... 850'000 m3/h

    1'500 ... 500'000 ACFM

    12.5 ... 4'200 t/h at 10bar/230°C

    27.5 ... 4'600 tons/h at 145psi/445°F

  • Max. process pressure

    Cl.150 ... 2500

  • Medium temperature range

    Compact version:

    -200°C ... 200°C

    -328°F ... 392°F



    Remote version:

    -200°C ... 1000°C

    -328°F ... 1832°F

  • Degree of protection

    Transmitter (Deltabar):

    IP67

    NEMA6P

  • Display/Operation

    Transmitter (Deltabar):

    4-line display

    3 push buttons

    Quick setup

    HistoROM

  • Outputs

    Transmitter (Deltabar):

    4 ... 20 mA

  • Digital communication

    Transmitter (Deltabar):

    HART

    PROFIBUS PA

    FOUNDATION Fieldbus

  • Hazardous area approvals

    Transmitter (Deltabar):

    ATEX

    FM

    CSA

    IEC

    TIIS

    NEPSI

Documents / Manuals / Software

Accessories / Spare parts

Nr
Order code
Specification

Please select your market / region